King 5500 Pellet Stove Manual: A Comprehensive Guide
This manual provides detailed instructions for the King 5500 pellet stove‚ covering installation‚ operation‚ maintenance‚ and troubleshooting for optimal performance.
Access free PDF downloads of the owner’s manual‚ alongside guides for related models like the 5500M and 5500XL‚ ensuring safe and efficient use.
The King 5500 pellet stove represents a robust and efficient heating solution for residential spaces. This fully automatic stove‚ available in models like the 5500M and 5500XL‚ boasts features such as auto-ignition and user-friendly digital controls‚ designed for years of reliable performance.
Understanding the intricacies of your stove is paramount for safe and effective operation. This manual serves as a comprehensive resource‚ guiding you through every aspect – from initial setup and proper venting to routine maintenance and troubleshooting common issues.
Accessing the official owner’s manual in PDF format is crucial. It provides detailed specifications‚ safety precautions‚ and operational guidelines specific to your King 5500 model‚ ensuring optimal heating and peace of mind.
Understanding the 5500M vs. 5500XL Models
Both the King 5500M and 5500XL are fully automatic pellet stoves‚ sharing core features like auto-ignition and digital controls for ease of use. However‚ key distinctions exist impacting heating capacity and overall performance.
The 5500XL generally offers a larger heating capacity compared to the 5500M‚ making it suitable for bigger spaces. While both models prioritize durability‚ the XL version may incorporate slight design enhancements.
Referencing the owner’s manual specific to your model (5500M or 5500XL) is vital. It details precise specifications‚ including dimensions‚ weight‚ pellet consumption rates‚ and electrical requirements‚ ensuring you understand your stove’s capabilities.
Safety Precautions and Warnings
Prioritize safety when installing and operating your King 5500 pellet stove. Always adhere to proper venting requirements to prevent carbon monoxide poisoning – a potentially fatal hazard. Never use flammable liquids to start or boost the fire.
Ensure the stove is installed by a qualified technician‚ following local codes and regulations. Regularly inspect the vent pipe for obstructions or damage. Keep combustible materials a safe distance from the stove.
The owner’s manual contains crucial warnings regarding operation and maintenance. Read it thoroughly before use. Never operate the stove with a damaged cord or plug‚ and disconnect power before cleaning or servicing.

Installation and Setup
Proper installation is crucial for safe and efficient operation of the King 5500. This includes correct venting‚ appropriate pellet fuel‚ and a careful startup procedure.
Proper Venting Requirements
Ensuring correct venting is paramount for the safe operation of your King 5500 pellet stove. The manual details specific requirements for venting systems‚ emphasizing the use of approved venting components only.
Typically‚ a double-wall‚ non-combustible vent pipe is necessary to prevent overheating and potential fire hazards. The vent pipe must maintain a specific diameter and rise vertically‚ adhering to local building codes and manufacturer guidelines.
Incorrect venting can lead to carbon monoxide buildup‚ a dangerous and potentially fatal situation. Always consult a qualified professional for installation and inspection to guarantee compliance and safety. Proper sealing of vent pipe sections is also critical to prevent leaks.
Pellet Fuel Specifications
The King 5500 pellet stove is designed to operate with high-quality pellet fuel that meets specific standards. Using the correct fuel ensures efficient combustion‚ minimizes ash buildup‚ and prolongs stove life.
Generally‚ pellets should be made from 100% hardwood‚ with a moisture content of less than 20%. Low-grade pellets with high moisture can cause operational issues and reduce heating efficiency.
The manual recommends using pellets that are certified by the Pellet Fuels Institute (PFI) to guarantee consistent quality. Avoid using pellets containing binders or additives‚ as these can create excessive ash and damage the stove’s components. Store pellets in a dry location to prevent moisture absorption.
Initial Stove Startup Procedure
Before the first use‚ ensure the King 5500 pellet stove is properly installed and vented according to the manual’s instructions. Fill the hopper with approved pellet fuel‚ verifying it’s dry and meets the specified quality standards.
Plug in the stove and power it on. The control panel will initiate a self-test. Follow the on-screen prompts to begin the startup sequence. The auger will begin feeding pellets into the burn pot.
Allow the igniter to heat up and initiate combustion. Monitor the startup process‚ ensuring a consistent flame develops. Adjust the settings as needed to achieve optimal burn characteristics.

Operating Instructions
The King 5500’s digital controls offer automated operation‚ precise heat adjustments‚ and convenient remote control functionality for comfortable and efficient home heating.
Understanding the Control Panel
The King 5500 pellet stove features an intuitive electronic control panel for managing all stove functions. This panel allows users to easily adjust heat output and burn rates‚ setting desired temperatures for optimal comfort. Key functions include power on/off‚ ignition control‚ and fan speed adjustments.
Users can navigate through various settings to customize the stove’s operation‚ including automatic ignition and programmed schedules. The display provides real-time information on stove status‚ pellet levels‚ and any error codes that may arise. Familiarizing yourself with the control panel is crucial for efficient and safe operation of your King 5500 pellet stove.
Ignition System Operation
The King 5500 pellet stove utilizes a fully automatic ignition system for convenient and reliable startup. Upon activation‚ the igniter heats up to initiate combustion of the pellets in the firepot. The control panel manages the ignition sequence‚ ensuring a safe and efficient lighting process.
If the stove fails to ignite after several attempts‚ an error code will display on the control panel‚ indicating a potential issue with the igniter or pellet supply. Regular inspection and replacement of the igniter (parts 80619/80481) are essential for maintaining optimal ignition performance. Proper pellet fuel is also crucial for successful ignition.
Adjusting Heat Output and Burn Rate
The King 5500 pellet stove offers adjustable heat output and burn rate settings via the control panel. Users can customize these settings to achieve desired comfort levels and optimize fuel consumption. Adjusting the air/fuel ratio is key to fine-tuning performance; allow approximately thirty minutes between adjustments for accurate assessment;
Lower burn rates provide longer burn times and reduced pellet consumption‚ while higher rates deliver maximum heat output. Experimenting with different settings allows users to find the ideal balance for their specific heating needs. Remember to monitor the stove’s performance after each adjustment.
Automatic Operation Mode
The King 5500 pellet stove features a fully automatic operation mode‚ simplifying heating management. This mode utilizes the stove’s internal sensors and controls to maintain a consistent temperature without manual intervention. The auto-ignition system initiates the burn cycle‚ and the stove automatically adjusts pellet feed and air supply.
Users can set a desired room temperature‚ and the stove will cycle on and off to maintain that level. This provides convenient and efficient heating‚ reducing the need for constant monitoring. The digital controls allow for easy programming and customization of the automatic settings.

Maintenance and Cleaning
Regular cleaning‚ including ash removal and heat exchanger maintenance‚ is crucial for optimal performance and longevity of your King 5500 pellet stove.
Regular Cleaning Schedule
Maintaining a consistent cleaning schedule is vital for the efficient and safe operation of your King 5500 pellet stove. Daily‚ inspect the firepot and remove any clinker buildup.
Weekly‚ thoroughly clean the glass door with a specialized pellet stove glass cleaner to maintain visibility. Empty the ash pan when it’s approximately one-quarter to one-half full‚ ensuring ashes are disposed of properly in a metal container with a lid.
Monthly‚ inspect and clean the heat exchanger using a vacuum attachment. A seasonal deep clean‚ before and after heating seasons‚ involves a comprehensive inspection of all components and a thorough cleaning of the venting system. Following this schedule ensures peak performance and extends the life of your stove.
Ash Removal Procedures
Proper ash removal is crucial for maintaining optimal performance and preventing potential hazards with your King 5500 pellet stove. Always allow ashes to cool completely – at least 12 hours – before handling.
Carefully remove the ash pan‚ ensuring it’s securely closed to prevent spills. Dispose of cooled ashes in a metal container with a tight-fitting lid‚ placing it away from combustible materials.
Avoid using a vacuum cleaner for ash removal unless it’s specifically designed for that purpose‚ as fine ash particles can damage the motor. Regularly emptying the ash pan – when it’s one-quarter to one-half full – prevents buildup and ensures efficient operation.
Cleaning the Heat Exchanger
Regular cleaning of the heat exchanger is vital for maintaining efficient heat output in your King 5500 pellet stove. Turn off and unplug the stove before beginning this process.
Remove the baffle and use a brush or vacuum with a brush attachment to gently remove soot and creosote buildup from the heat exchanger fins. Avoid excessive force‚ which could damage the delicate fins.
A clean heat exchanger maximizes heat transfer and improves overall stove performance. Inspect the heat exchanger for any obstructions or damage during cleaning. This should be done periodically as part of your routine maintenance schedule.
Cleaning the Vent Pipe
Maintaining a clean vent pipe is crucial for safe and efficient operation of your King 5500 pellet stove‚ preventing potential hazards like chimney fires. Always ensure the stove is cool before starting this process.
Disconnect the vent pipe sections and inspect for creosote buildup. Use a vent cleaning brush of the correct size to thoroughly scrub the interior of each pipe section. A vacuum can help remove loosened debris.
Reassemble the vent pipe securely‚ ensuring all connections are tight. Regular vent pipe cleaning‚ typically annually‚ is recommended for optimal performance and safety. Inspect for corrosion or damage during cleaning.

Troubleshooting Common Issues
This section details solutions for frequent problems like ignition failures‚ low heat output‚ error codes‚ and auger jams‚ ensuring reliable stove operation.
Stove Not Igniting
If your King 5500 pellet stove fails to ignite‚ several factors could be at play. First‚ verify the pellet fuel is dry and flowing freely to the auger. A clogged auger or low fuel level prevents proper ignition.
Next‚ inspect the igniter (parts 80619/80481) for damage or failure. Replacement may be necessary. Ensure the igniter is receiving power; check the control board and wiring connections. Confirm the stove is receiving adequate electrical supply.
Also‚ a blocked vent pipe can hinder ignition. Finally‚ consult the error code displayed on the control panel for specific diagnostic information‚ as it pinpoints the issue.
Low Heat Output
Experiencing low heat output from your King 5500 pellet stove can stem from several causes. Insufficient pellet fuel is a primary suspect; ensure the hopper is adequately filled and the auger is delivering pellets consistently.
Check for obstructions in the vent pipe‚ as restricted airflow reduces heating efficiency. A dirty heat exchanger hinders heat transfer‚ requiring thorough cleaning. Adjusting the air/fuel ratio can optimize combustion; start with small adjustments‚ allowing 30 minutes between each change.
Verify the blower motor is functioning correctly‚ as it distributes heated air. Finally‚ examine the pellet quality – wet or low-grade pellets burn inefficiently.
Error Codes and Their Meanings
The King 5500 pellet stove utilizes error codes to diagnose operational issues. Understanding these codes is crucial for effective troubleshooting. While specific codes aren’t detailed in the provided snippets‚ a malfunctioning auger motor often triggers an error‚ halting pellet delivery.
Ignition failures frequently generate codes‚ indicating problems with the igniter or related circuitry. Low hopper levels or obstructions can also produce error signals. Consult the complete owner’s manual for a comprehensive list of codes and their corresponding solutions.
Regularly checking the control board for error displays is a proactive maintenance step.
Auger Jamming Issues
Auger jamming is a common issue with pellet stoves‚ including the King 5500. This occurs when pellets bind within the auger tube‚ preventing fuel delivery. Causes include damp or improperly stored pellets‚ foreign objects entering the hopper‚ or auger motor malfunctions.
To resolve jamming‚ first disconnect power. Then‚ carefully remove pellets from the auger tube and hopper. Inspect for obstructions. Ensure pellets are dry and free of debris. If the issue persists‚ the auger motor or assembly may require inspection or replacement.
Preventative maintenance‚ like proper pellet storage‚ minimizes jamming risks.

Component Overview

The King 5500 utilizes key components like the auger motor‚ igniter‚ blower motor‚ and control board‚ all crucial for efficient operation and maintenance.
Auger Motor and Assembly
The auger motor is a vital component‚ responsible for delivering pellet fuel from the hopper to the burn pot. Proper function ensures consistent fuel supply and efficient combustion. The assembly includes the auger itself‚ a rotating screw-like mechanism‚ and the motor that drives it.
Regular inspection is crucial; check for obstructions or damage that could cause jamming. A malfunctioning auger motor can lead to inconsistent heat output or stove shutdown. Ensure the motor is securely mounted and the wiring connections are tight. Replacement parts‚ like the 80619/80481 igniter‚ are often referenced alongside auger maintenance‚ indicating their interconnected importance within the system.
Addressing auger jamming promptly prevents further damage and maintains optimal stove performance.

Igniter Replacement (80619/80481)
The igniter‚ identified by part numbers 80619 or 80481‚ is essential for initiating combustion within the King 5500 pellet stove. A faulty igniter prevents the pellets from igniting‚ resulting in a no-start condition. Replacement is a relatively straightforward process‚ often demonstrated in instructional videos available online.
Before replacing‚ ensure the stove is completely cooled and disconnected from power; Carefully remove the old igniter and install the new one‚ ensuring a secure connection. Proper installation is critical for reliable operation.
Refer to the owner’s manual or online resources for detailed step-by-step instructions and safety precautions. A functioning igniter is key to consistent and efficient stove performance.
Blower Motor Functionality
The blower motor in the King 5500 pellet stove is crucial for distributing heated air throughout the room and maintaining proper combustion. It draws air into the stove for the burn process and expels exhaust gases through the venting system. Proper functionality ensures efficient heating and safe operation.
The blower speed is typically adjustable via the control panel‚ allowing users to customize heat output. A malfunctioning blower motor can lead to reduced heating performance or even a stove shutdown.
Regular inspection and cleaning of the blower motor are essential for optimal performance and longevity. Ensure the fan blades are free from obstructions and the motor is operating smoothly.
Control Board Diagnostics
The control board is the “brain” of the King 5500 pellet stove‚ managing all operational functions‚ from ignition to fuel delivery and blower speed. Diagnosing issues with the control board often involves interpreting error codes displayed on the control panel.
These codes provide valuable clues about the nature of the problem‚ such as a faulty sensor‚ auger malfunction‚ or overheating. Refer to the manual’s error code section for specific interpretations.
Basic diagnostics include checking wiring connections and visually inspecting the board for any signs of damage. More complex issues may require professional servicing.

Advanced Features
Explore the King 5500’s advanced capabilities‚ including air/fuel ratio adjustments‚ digital control settings‚ remote operation‚ and convenient auto-ignition functionality.
Air/Fuel Ratio Adjustment
Fine-tuning the air/fuel ratio on your King 5500 pellet stove is crucial for achieving optimal combustion and heat output. Adjustments impact burn quality and efficiency‚ requiring patience and observation. Remember that changes don’t yield immediate results; allow approximately thirty minutes between each adjustment to assess the effects.
Start with factory baseline settings and make small‚ incremental changes. Observe the flame pattern – a lively‚ blue flame indicates efficient combustion. A lazy‚ yellow flame suggests a need for adjustment. Carefully monitor exhaust temperatures and pellet consumption rates to gauge performance. Document your changes to easily revert if necessary.
Proper adjustment minimizes creosote buildup and maximizes fuel economy.
Digital Control Settings
The King 5500 pellet stove features intuitive digital controls for precise operation. These settings allow customization of heat output‚ burn rates‚ and automatic operation schedules. Explore the menu to adjust fan speed‚ influencing heat distribution throughout your space. Utilize the programmable timer to set start and stop times‚ optimizing comfort and fuel efficiency.
Familiarize yourself with the various modes‚ including manual and automatic operation; The control panel displays error codes‚ providing valuable diagnostic information. Regularly check settings to ensure they align with your heating preferences and environmental conditions.
Refer to the manual for detailed explanations of each setting and its impact on stove performance;
Remote Control Operation
The King 5500 pellet stove offers convenient remote control functionality‚ enhancing user experience and accessibility. This allows you to adjust settings‚ ignite the stove‚ and monitor operation from a distance‚ providing ultimate comfort and control. Ensure the remote control is properly paired with the stove following the instructions in the manual.
Utilize the remote to modify heat output‚ fan speed‚ and activate automatic ignition without needing to physically interact with the stove. Check battery levels regularly to maintain reliable operation.
The remote provides a streamlined way to manage your heating environment‚ maximizing convenience and efficiency.
Understanding Auto-Ignition
The King 5500 pellet stove features an auto-ignition system for effortless startup. This system utilizes a glow plug (80619/80481) to ignite the pellets automatically‚ eliminating the need for manual lighting. The control board manages the ignition sequence‚ ensuring a safe and reliable start-up process.
During auto-ignition‚ the auger delivers pellets to the firepot while the igniter heats up. Once the pellets ignite‚ the system transitions to normal burning mode.
If auto-ignition fails‚ consult the troubleshooting section of the manual for potential causes and solutions. Proper maintenance of the igniter is crucial for consistent performance.

Technical Specifications
The King 5500 boasts specific dimensions‚ weight‚ heating capacity‚ electrical needs‚ and pellet consumption rates detailed in the owner’s manual.
Dimensions and Weight
Understanding the physical characteristics of the King 5500 pellet stove is crucial for proper installation and ensuring it fits comfortably within your designated space. While specific dimensions can vary slightly between the 5500M and 5500XL models‚ the owner’s manual provides precise measurements for both.
Generally‚ users should anticipate a substantial weight due to the stove’s robust construction and durable materials. This weight is a key factor when considering flooring support and ease of maneuvering during installation or maintenance. The manual details the exact weight in pounds‚ allowing for informed planning. Accurate dimensions and weight information are vital for safe and efficient operation.
Heating Capacity
The King 5500 pellet stove is designed to provide substantial heat‚ making it a viable option for warming various spaces within your home. The heating capacity‚ measured in BTUs (British Thermal Units)‚ determines the area the stove can effectively heat.
The owner’s manual specifies the maximum heating output of the 5500‚ along with guidelines for calculating the appropriate stove size based on your home’s square footage and insulation levels. Factors like ceiling height and climate also influence the effective heating range. Understanding these specifications ensures optimal performance and efficient fuel consumption. Properly sizing the stove to your needs maximizes comfort and minimizes operating costs.
Electrical Requirements
The King 5500 pellet stove requires a dedicated electrical connection for safe and reliable operation. The manual details specific voltage‚ amperage‚ and circuit requirements to prevent electrical hazards and ensure proper functionality of all stove components. Typically‚ a standard 120V household outlet is sufficient‚ but a dedicated circuit is strongly recommended.
It’s crucial to verify your home’s electrical system meets these specifications before installation. Improper wiring or overloading circuits can lead to malfunctions or even fire hazards. The manual emphasizes the importance of following all local electrical codes and consulting a qualified electrician if you have any doubts regarding the electrical setup.
Pellet Consumption Rates
The King 5500 pellet stove’s fuel consumption varies based on heat output settings and environmental factors. The manual provides estimated pellet consumption rates for different burn levels‚ allowing users to predict fuel needs and manage costs effectively. Lower settings naturally consume less fuel‚ extending burn times and minimizing expenses.
Factors like insulation‚ outdoor temperature‚ and desired room temperature significantly impact consumption. Understanding these rates helps optimize stove performance and maintain consistent heating. The manual advises monitoring pellet levels regularly and adjusting settings to achieve the desired balance between heat output and fuel efficiency.